Operator’s Manual TF-DSQ Probe Calibration and Deskew Fixture

Page 2 - Deskew Fixture

Operator's Manual 10 TF-DSQ-OM-E RevC Assembling the TF-DSQ fixture See the fixture overview to identify individual components. System assembly

Page 3 - Warranty

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 11 TF-DSQ Oscilloscope Connection The TF-DSQ fixture is connected to either an unused os

Page 4 - TABLE OF CONTENTS

Operator's Manual 12 TF-DSQ-OM-E RevC Probe Connection to TF-DSQ The TF-DSQ provides multiple probe connectors for various kinds of probes. Prob

Page 5

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 13 Figure 4-3. Differential Probe Properly Connected to the Fixture (Browsing Configur

Page 6 - TF-DSQ Overview

Operator's Manual 14 TF-DSQ-OM-E RevC Probe Calibration Probe Calibration Menu Accessing the Probe Calibration Menu The probe calibration menu c

Page 7

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 15 Note: The Cal Skew Ref field (and others) shows EXT for External Trigger Input. This

Page 8 - TF-DSQ Connections

Operator's Manual 16 TF-DSQ-OM-E RevC PROBE DESKEW INFORMATION The probe deskew information contains the measured skew between the probe in the

Page 9 - TF-DSQ Fixture Elements

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 17 Basic Probe Calibration The TF-DSQ fixture is used to calibrate probes. Prior to begi

Page 10 - Operator's Manual

Operator's Manual 18 TF-DSQ-OM-E RevC Deskew Only Pressing this button performs only the deskew calibration of the probe on the specified channe

Page 11

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 19 Common Mode Voltage Selection The TF-DSQ fixture calibrates probes differentially or

Page 12 - Probe Connection to TF-DSQ

TF-DSQ Probe Calibration and Deskew Fixture Operator's Manual July, 2009

Page 13 - TF-DSQ-OM-E RevC

Operator's Manual 20 TF-DSQ-OM-E RevC Two channels are properly deskewed relative to each other when the difference between the deskew values en

Page 14 - Probe Calibration

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 21 The following example illustrates this scenario: Two probes are used in a system. The

Page 15 - PROBE DC INFORMATION

Operator's Manual 22 TF-DSQ-OM-E RevC Deskew Risetime Adjustment Theory Two scenarios require adjustment of the deskew values to account for ris

Page 16

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 23 Now, let's assume that these probes are applied to signals with the same risetim

Page 17 - Basic Probe Calibration

Operator's Manual 24 TF-DSQ-OM-E RevC The TF-DSQ fixture, in accordance with the philosophy of requiring only one calibration in the fixture, ha

Page 18

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 25 The gain and offset correction applied during DC calibration affects the voltage mea

Page 19 - Theory of Operation

Operator's Manual 26 TF-DSQ-OM-E RevC In this case, the outer conductor connects the oscilloscope's ground to the circuit's ground, an

Page 20

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 27 Despite differential probes measuring differentially, they can be used to measure com

Page 21

Operator's Manual 28 TF-DSQ-OM-E RevC Operating Environment Before using your accessory, ensure that its operating environment will be maintaine

Page 22

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 29 Electromagnetic Emissions:  EN 55011/A2:2002, Radiated and conducted emissions (Cla

Page 23

LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 578-6020, Fax: (845) 578 5985 Warranty LeCroy warrants this os

Page 24 - DC Calibration Theory

Operator's Manual 30 TF-DSQ-OM-E RevA Index C calibration: probe, 13 P probe calibration, 13 T TF-DSQ, 5 absolute skew, 19 advanced probe calibr

Page 25 - Probing Basics

Thank you for purchasing a TF-DSQ Probe Calibration and Deskew Fixture.

Page 26

Operator's Manual iv TF-DSQ-OM-E RevC TABLE OF CONTENTS TF-DSQ Overview ...

Page 27

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC v Safety Precautions ...

Page 28 - CE Declaration of Conformity

Operator's Manual 6 TF-DSQ-OM-E RevC TF-DSQ Overview Probe Calibration with the TF-DSQ Fixture The TF-DSQ fixture is used in conjunction with th

Page 29 - Low-Voltage Directive

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 7 Probe Calibration Steps with the TF-DSQ Fixture Probe calibration is accomplished with

Page 30

Operator's Manual 8 TF-DSQ-OM-E RevC TF-DSQ Connections TF-DSQ Fixture Overview The TF-DSQ fixture comes in a soft case containing a CD with .pd

Page 31 - TF-DSQ Probe Calibration

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 9  A ProLink extender  A BNC to SMA adapter (not pictured) TF-DSQ Fixture Elements